FDT
Visual Thresholds

The Frequency Doubling Technology (FDT) perimeter is a portable instrument designed for fast and effective detection of visual field loss1. This instrument (Welch Allyn, Skaneateles, N.Y., and Carl Zeiss Meditec, Dublin, Calif.) was launched in 1997, and has been used successfully worldwide.


Numerous studies have shown that it offers a high sensitivity and specificity in the detection of early glaucomatous damage, and in other disorders ranging from ocular, retinal, neurological and neuro-ophthalmological causes2-5. FDT offers many advantages in that it is easy to administer and interpret, liked by most patients, not greatly affected by refractive error and cataract, has high test-retest reliability, offers rapid screening tests, and has different full threshold programs.

The excellent clinical performance offered by the original FDT, along with the numerous studies over the past years have led to the release of the Humphrey Matrix, the second generation of the FDT perimeter. Enhancements were added to address the limitations of the former version and to increase the diagnostic capabilities for clinical use. In the Matrix, the spatial extent and topographical representation of visual field defects has been improved by the presence of additional tests that use smaller and more numerous targets spaced at smaller intervals.

The use of FDT perimetry in a clinical setting began in the late 90’s, thus further longitudinal studies are needed to evaluate the role of FDT in monitoring progressive field loss, the effectiveness in predicting glaucomatous defects, the correlation it has to structural loss (if any) and the improved ability of the second generation instrument.

01 FDT

02 FDT

FDT perimetry is based on a phenomenon described by Kelly6 about 40 years ago, who observed that when an achromatic sinusoidal grating of low spatial frequency undergoes counterphased flickering at a high temporal frequency, the apparent spatial frequency of the grating appears to be doubled. The short movie on the right (double click on the image) shows this effect, in that the frequency of light and dark bars of the stimulus appear to be twice the actual number when the temporal frequency of the counterphased flickering is increased. He reported that this occurred for sinusoidal gratings having a spatial frequency less than approximately 3 cyc/deg undergoing a counterphase flickering at a temporal frequency greater than 7 Hz. It was later suggested that this nonlinear response of the visual system is due the appearance of a second-harmonic distortion that may involve rectification and response compression7, 8. Other investigators have also reported fractional perceived spatial frequency when different temporal frequencies are utilized9-11.

The FDT procedure first attracted interest as a clinical diagnostic test procedure based on the fact that flicker sensitivity and flicker perimetry has been found to be useful for evaluation of different ocular and neurologic disorders, and can even reveal early losses before they can be determined with conventional clinical test procedures. Because FDT utilizes a high temporal frequency flicker rate, this approach seemed to be potentially appealing, particularly in view of the fact that flicker sensitivity measurements are often resistant to many different artifactual results that may be present. Initial attempts to use FDT as a clinical diagnostic procedure were informative, but also revealed findings suggesting a number of changes that were needed. Many of these changes are outlined in previous publications during the early evaluations of FDT1, 4. Since that time, many other discoveries have also been revealed, as briefly described in this write-up.


The
Humphrey Matrix
            The Next Generation

The Humphrey Matrix was released in April 2005 with the aim of providing significant enhancements to the diagnostic capabilities. Additional tests having smaller targets and increased number of tested locations to improve the spatial resolution of VF defects have been created without greatly effecting the variability and sensitivity resolution27, 28. Matrix offers tests with different stimulus presentation patterns, in addition to the test found in the previous version. Improvements have also been made to the instrument hardware and software, making it easier, reliable and more efficient to use

03 FDT

05 FDT

Matrix
            Stimuli

The 10º targets in the original FDT have provided a good sensitivity and specificity in detecting VF loss, however, small localized defects and subtle changes could be missed. The example below shows how small defects, like that resulting from a small branch occlusion, can be missed with large FDT targets, yet picked up with SAP and smaller FDT targets found in Matrix. This restricted ability to spatially localize VF defects limits the ability of the original FDT in detecting subtle defects, monitoring progression and classifying neuro-ophthalmic disorders.

One of the first prototypes leading up to Matrix involved using smaller 4º square stimuli spaced 6º apart, with a greater number of tested locations in pattern similar to the 24-2 HFA II pattern29. Studies have shown that this type of testing improves the spatial localization of VF defects, which improves the ability to detect and monitor visual field loss, while maintaining a similar sensitivity resolution, low test-retest variability and an increases dynamic range of sensitivity compared to previous version29, 30. In order to ensure this, the smaller targets have a higher spatial frequency of 0.5 cyc/deg (as opposed to 0.25 cyc/deg in FDT) and a lower temporal frequency of 18Hz (in comparison to 25 Hz).


The Matrix perimeter makes use of targets similar to those in the prototype. Four tests have been added, named according to the VF eccentricity examined: 24-2, 30-2, 10-2 and Macula. The tests differ in pattern presentations, test duration, number of catch trials, VF eccentricity, number and pattern of visual field locations tested and characteristics of the stimulus used (size and temporal frequency). All Matrix tests use a stimulus having a spatial frequency of 0.5 cyc/deg.

The 24-2 and 30-2 tests use 5º targets that have a temporal counterphase flickering rate of 18 Hz, whereas the 10-2 and Macula test use 2º targets with a temporal flickering rate of 12 Hz (that give a flicker sensitivity as opposed to FD response). Table 1 below lists the specific characteristics of each of the tests found in the Humphrey Matrix.

04 FDT

TIT A Message From Dr Arroyo

I would like to welcome you on behalf of my team members and myself and let you know what a pleasure it is to have you in our office. There are a few things I would like for you to know.

Demo

TIT New Patien Forms

Thank you for scheduling your appointment with our office. Please fill out the forms below.

Your do not need to fill out the NES and MPP tabs unless you are scheduling a consultation for our Migraine Protocol or Bio-Energetic theraphy.

If you have any questions or concerns please contact our office at
(281) 419-3355